Fe/NFe Coating Thickness Gauge
モデル :
ABT-00170FC
ABT-00170FC NEW
Fe/NFe Coating Thickness Gauge
● This gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings,
e.g. paint, enamel, chrome on steel, and insulating coatings,
e.g. paint and anodizing coatings on nonferrous metals.
Fe/NFe Coating Thickness Gauge
● This gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings,
e.g. paint, enamel, chrome on steel, and insulating coatings,
e.g. paint and anodizing coatings on nonferrous metals.
ABT-00170FC NEW
Fe/NFe Coating Thickness Gauge
● Measuring principle: Magnetic induction (F-probe) and eddy current (N-probe)
● Measuring range: 0 to 1300um (0 to 51.2mils)
● Accuracy: ± (3% of readings+2um); ± (3% of readings+0.078mils)
● Resolution: 0um-999um (1um), 1000um-1300um (0.01mm);
0mils-39.39mils (0.01mils), 39.4mils-51.2mils (0.1mils)
● Calibration: One to four point calibration, zero calibration
● Data Group: One direct group (readings not bestored to memory), four general group (readings can be stored),
and each group have individual statistics, alarm settings and calibration
● Statistics: No. of readings, mean, minimum, maximum and standard deviation
● Units: um, mm and mils
● Alarm: User can set the high/low alarm, and alarm icon displayed on LCD when over the limit
● Minimum curvature radius: convex 1.5mm(59mils) and concave 25mm(984mils)
● Minimum measuring size: Diameter 6mm(236mils)
● Minimum thickness of substrate: F-probe: 0.5mm(0.02"), N-probe: 0.3mm(0.012")
● Computer interface: Download data via USB interface
● Power supply: Two 1.5v AAA battery
Fe/NFe Coating Thickness Gauge
● Measuring principle: Magnetic induction (F-probe) and eddy current (N-probe)
● Measuring range: 0 to 1300um (0 to 51.2mils)
● Accuracy: ± (3% of readings+2um); ± (3% of readings+0.078mils)
● Resolution: 0um-999um (1um), 1000um-1300um (0.01mm);
0mils-39.39mils (0.01mils), 39.4mils-51.2mils (0.1mils)
● Calibration: One to four point calibration, zero calibration
● Data Group: One direct group (readings not bestored to memory), four general group (readings can be stored),
and each group have individual statistics, alarm settings and calibration
● Statistics: No. of readings, mean, minimum, maximum and standard deviation
● Units: um, mm and mils
● Alarm: User can set the high/low alarm, and alarm icon displayed on LCD when over the limit
● Minimum curvature radius: convex 1.5mm(59mils) and concave 25mm(984mils)
● Minimum measuring size: Diameter 6mm(236mils)
● Minimum thickness of substrate: F-probe: 0.5mm(0.02"), N-probe: 0.3mm(0.012")
● Computer interface: Download data via USB interface
● Power supply: Two 1.5v AAA battery